10-4 SPARC Enterprise M4000/M5000 Servers Service Manual December 2010
10.1.1 Accessing the 60-mm Fan Module
1. From the XSCF Shell prompt, use the replacefru command to disable the fan
to be removed.
The replacefru command is menu-driven. replacefru will continue while the
fan is removed and then test the fan. Refer to Section 4.3.1, “Removing and Replacing
a FRU” on page 4-7 for more information.
Caution To prevent the equipment rack from tipping over, you must deploy the
antitilt feature, if applicable, before you slide the server out of the equipment rack.
Caution When drawing out the M4000/M5000 server to the front, release the cable
tie holding the PCI cables on the rear of the server.
2. Deploy the rack’s antitilt features (if applicable) and slide the server out of the
equipment rack.
See Section 5.1.1, “Sliding the Server Out of the Equipment Rack” on page 5-2.
Caution Use proper ESD grounding techniques when handling components. See
Section 1.1, “Safety Precautions” on page 1-1.
XSCF> replacefru