could not transfer job(s)
Job initialization error
pending jobs
Job is in progress or has not been cleaned up
update process aborted
Update process was aborted because the CMS was booted
Action
l Execute the CLEANUP function (see "Cleanup Wizard" on page 84).
l Copy the errored job and restart it.
boot timeout
Timeout during boot process
timeout wait for boot inactive
Error while booting the update agent
Action
l Check the boot sequence in the BIOS and correct it if necessary.
In the BIOS setup, LAN/PXE must be the first entry in the boot
sequence.
l Then restart the managed server.
agent offline
Update agent not found
Action
l Rectify any connection problems.
l If this does not help, reinstall the update agent.