Fujitsu V3.1 Manual de usuario

Busca en linea o descarga Manual de usuario para Redes Fujitsu V3.1. Fujitsu V3.1 User's Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 362
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente

Indice de contenidos

Pagina 1 - Edition October 2012

User Guide - EnglishServerView SuiteServerView Virtual-IO Manager V3.1User GuideEdition October 2012

Pagina 2 - Copyright and trademarks

10 ServerView Virtual-IO Manager

Pagina 3 - Contents

4 Configurationfind a detailed description on the interfaces in the ServerView ManagementBlade manual for BX600.Check the following settings in the ma

Pagina 4

To check the parameter setting in the Remote Manager of the man-agement blade, choose (1) Management Agent – (3) System Infor-mation – (11) Automatic

Pagina 5

4 ConfigurationConfiguration using the Web interfaceYou can configure the network parameters of an I/O connection blade usingthe Web interface of the

Pagina 6

Configuration using the Remote ManagerYou can also configure the network parameters of the I/O connection bladesusing the Remote Manager of the manage

Pagina 7

4 ConfigurationFor Fibre Channel switch modules (select FC Switch Blade), youmust also specify access data for the parameters Set Login User-name and

Pagina 8

For the external switch to which an IBP module is connected for admin-istration, you have to ensure that the Spanning Tree Protocol (STP) isswitched o

Pagina 9

4 ConfigurationFigure 15: BX600: Network - OverviewPort 0/11 for an IBP 10/6 or port 0/31 for an IBP 30/12 must be connected tothe central management

Pagina 10

Otherwise, you may have a situation whereby the corresponding IBP modulecan no longer be accessed from the central management station. If thishappens,

Pagina 11 - 1 Introduction

4 ConfigurationExample(Vty-0) #show uplink-setUplink External External External Link Port IGMPSet Name ports active ports backup ports state Backup sn

Pagina 12 - 1.2 System requirements

is assigned to this uplink set (because, for example, 1_NET is to be deleted),then you can restore the LAN connection to the IBP by adding the port to

Pagina 13

1 IntroductionYou use the ServerView Virtual-IO Manager (Virtual-IO Manager or VIOM forshort) software to manage the input/output parameters (I/O para

Pagina 14 - 1.3 Supported Hardware

4 Configurationl Define the connection of the IBP modules with the network, see section"Connecting IBP modules" on page 115l Add the blade s

Pagina 15 - Managed BX400 blade servers

4.2.1.1 LAN hardware configurationUsing IBP ModulesThe following LAN connection blades in IBP mode can be used in fabric 1(connection bay 1) and fabri

Pagina 16

4 ConfigurationTherefore, if you do not want to use any routing, all combinations are possibleeven with non-VIOM-capable I/O connection blades. You mu

Pagina 17 - Managed BX900 blade servers

4.2.2 Configuring the BX400 management bladeThe blade server must be fitted with at least one S1 management blade.The BX400 management blade has a use

Pagina 18

4 ConfigurationTo check the parameter setting in the Web interface open the Com-ponents section and select System – System Unit. The System Infor-mati

Pagina 19

You configure the network parameters of an I/O connection blade as follows:l Activate the Enable DHCP option under Management Port Settings ifthe conn

Pagina 20

4 ConfigurationPlease note that before you activate blade server management, sev-eral uplink ports of a LAN connection blade in IBP mode form a stat-i

Pagina 21

Figure 16: BX400: Network - OverviewThe I/O connection blades must be connected to the central management sta-tion via their management port.4.2.5 Swi

Pagina 22 - Access to the link collection

4 Configurationmonitoring, spanning tree protocol, VLAN, etc. The entire stack will appearas a single IBP.You find a detailed description about Switch

Pagina 23

4.3.1 Supported hardware configurations for the connectionbladesThe following connection blades are supported in a BX900:l The connection blades PY CB

Pagina 24 - 1.7 Typographic conventions

1 IntroductionVIOM provides an easy-to-use Web-based graphical user interface, whichyou can launch using the ServerView Operations Manager. Using this

Pagina 25 - 2.1 Virtual addresses

4 Configurationfabric 1, fabric 2, fabric 3, and fabric 4.Bay 1 (Bay 3) (Bay 5) (Bay 7) Bay 2 (Bay 4) (Bay 6) (Bay 8)PY CB Eth Switch/IBP 1Gb36/8+2 in

Pagina 26

4.3.1.2 Fibre Channel hardware configurationYou can install the Fibre Channel switch blades in fabric 2 or fabric 3. Theycan be operated in two differ

Pagina 27

4 Configurationthe version via the Web interface.If your firmware version is lower than the version required, you mustupdate it to the required firmwa

Pagina 28

automatic and remove and insert all blades or perform a power-off andpower-on of the blade server chassis.l To ensure that the blade server names in t

Pagina 29

4 ConfigurationYou configure the network parameters of an I/O connection blade as follows:l Activate the Enable DHCP option under Management Port Sett

Pagina 30

You configure the network parameters of an I/O connection blade as follows:l In the Remote Manager, choose (1) Management Agent – (6) Con-nection Blad

Pagina 31

4 Configuration4.3.4 Connecting IBP modulesThe PY CB Eth Switch/IBP 1Gb 36/8+2, PY CB Eth Switch/IBP 1Gb 36/12LAN, PY CB Eth Switch/IBP 1Gb 18/6, and

Pagina 32

Figure 17: BX900: Network - OverviewThe I/O connection blades must be connected to the central management sta-tion via their management port.4.3.5 Swi

Pagina 33 - Figure 4: Typical uplink sets

4 ConfigurationThe stacking software configures each device tables and registers to supportall switching functions, for example, switching, link aggre

Pagina 34 - "Single" networks

It is also important that the members of a stack have a unique "userassigned" name in the MMB and that the stack member IDs of the par-ticip

Pagina 35

oRed Hat RHEL5.6/5.7/5.8oRed Hat RHEL 6, 6.1/6.2In Japan: Novell SLES is not supported.ServerView Virtual-IO Manager can also be installed in Virtual

Pagina 36

4 Configurationl The PRIMERGY rack server must be in the list of supported servertypes.l The system BIOS and the iRMC firmware must fulfill VIOM requi

Pagina 37

For further information on the server list, see the "ServerView OperationsManager" user guide.l For correct operation in case of power loss

Pagina 38

4 ConfigurationAlthough VIOM does not guarantee that boot images created for one servertype also work with another server type, VIOM also supports the

Pagina 39

l Profiles with onboard CNA configuration cannot be assigned toservers which do not have an onboard CNA controller.l Only I/O channels on master slots

Pagina 40 - Dedicated service networks

4 ConfigurationRX300 S7Figure 20: RX300 S7 connection panel on the rear1 PCI slot 12 PCI slot 23 PCI slot 34 PCI slot 45 Shared LAN connector (LAN 1)6

Pagina 41

TX300 S7 and RX350 S7Figure 21: TX300 S7 connection panel on the rear1 PCI slot 92 PCI slot 83 PCI slot 74 PCI slot 65 PCI slot 56 PCI slot 47 PCI slo

Pagina 42 - Service VLAN networks

4 ConfigurationYou add the server to the ServerView server list using the server browser ofthe ServerView Operations Manager. To do this, choose Admin

Pagina 43 - 2.5 Server profiles

5 Virtual-IO Manager user interfaceThis chapter contains a general introduction to the Virtual-IO Manager(VIOM) describing:l The structure of the Virt

Pagina 44

5 Virtual-IO Manager user interfaceThe window is divided into three areas:l The ServerView Suite headerl The menu barl The work area with the tree str

Pagina 45

Button Selectionon the leftDisplay on the rightServerListFive tabs are displayed in the area on the right (see"Tabs" on page 142).All Server

Pagina 46 - PRIMERGY rack servers

1 Introduction1.3 Supported HardwareManaged BX600 blade serversSupported systems: BX600 S3 with MMB S3. For information on the requiredfirmware versio

Pagina 47

5 Virtual-IO Manager user interfacel Server list (default)l ProfilesYou switch between the two views by clicking the Server List and Profilesbuttons.

Pagina 48

When you select Server List (standard) on the left of the work area, the AllServer server group is displayed according to the ServerView server list a

Pagina 49

5 Virtual-IO Manager user interfacel Select a folder to show all contained profiles in the profiles table in theServer Profiles view in the area on th

Pagina 50

Figure 25: Virtual-IO Manager tabShow LicensesDisplaying information on the licenses assigned (see section "Dis-playing license information"

Pagina 51

5 Virtual-IO Manager user interface5.3.2 Setup tabUsing this tab, you specify whether an object is to be managed with VIOM ornot.l For a blade server

Pagina 52

responding blade server is shown. The table provides the following infor-mation:Column SignificanceName Name of the serverStatus Manage status of the

Pagina 53

5 Virtual-IO Manager user interfacel Fault Statel State CausesThe (Causes or State Causes) state cause is not at all a fault. It is simply astate mark

Pagina 54

passwords, which VIOM can use to access these servers. For detailssee "Authentication dialog box (single blade server)" on page 231,"Au

Pagina 55

5 Virtual-IO Manager user interfaceRestore IBP button to write the configuration saved internally in theVIOM database to the IBP module.Delete Configu

Pagina 56

delete existing ones, as well as copy definitions from one connection blade toanother.In the upper left part of the Graphic tab there is the rear view

Pagina 57

In Japan, BX600 blade servers are not supported.Managed BX400 blade serversSupported systems: BX400 with MMB S1. For information on the requiredfirmwa

Pagina 58

5 Virtual-IO Manager user interfaceEditClick Edit to edit an existing uplink set. The Edit Uplink Set wizard islaunched in which you can change the co

Pagina 59

Figure 28: Details tab on the Ext. LAN Connections tabYou can sort the table by the columns IBP, Uplink Set, and Network.NewClick New to define a new

Pagina 60 - 7. Click Next

5 Virtual-IO Manager user interfaceFigure 29: Server Configuration tabThe table contains one entry for each slot of the blade servers selected in thes

Pagina 61

Column SignificanceState Power stateSpare Indicates whether or not the slot is a spare slot. You change thedefinition of a slot as a spare slot direct

Pagina 62

5 Virtual-IO Manager user interfaceInventory BootClick Inventory Boot to re-create the inventory table of the selectedserver blade or PRIMERGY rack se

Pagina 63

Forced Power OffSwitches off the server irrespective of the status of the operatingsystem.Update StatesClick Update States to update the display in th

Pagina 64

5 Virtual-IO Manager user interfaceBootStart the server blade(s) and PRIMERGY rack server(s).ShutdownSwitch off the server blade(s) and PRIMERGY rack

Pagina 65

Figure 30: Chassis Configuration tabThe defined networks are listed in a rectangular box for each connection baywith an IBP connection blade. In the e

Pagina 66

5 Virtual-IO Manager user interfaceThe slots are displayed as smaller rectangles (Slot 1, Slot 2, Slot 3, …)below the rectangle that contains the list

Pagina 67

Figure 31: Server Profiles viewIf in the Server Profiles view in the area on the left a folder is selected, allserver profiles in this folder are show

Pagina 68

1 IntroductionThe Virtual-IO Manager can only manage BX400 chassis with S1management blades (MMB S1) that are assembled with the fol-lowing:l In fabri

Pagina 69

5 Virtual-IO Manager user interfaceColumn SignificanceNetwork The name of the network defining the dedicated LAN con-nectionComment forA more detailed

Pagina 70

Context menuSeveral actions for a server profile can be choosen from the context menu(click right mouse button):Edit ProfileThe Edit Server Profile wi

Pagina 71

5 Virtual-IO Manager user interfaceNextOpens the next step in the wizard.FinishExecutes the wizard with your settings.CancelCancels the wizard workflo

Pagina 72

The Create Network for IBP wizard comprises several dialog boxes toguide you through the individual steps. All required steps are displayed in thetree

Pagina 73

5 Virtual-IO Manager user interfaceSingle network (selected by default)Creates an uplink set with a network. The uplink set and the networkhave the sa

Pagina 74

Name of networkName for the internal network.5.4.1.3 Edit Properties step (Create Network wizard - single /VLAN network)Edit Properties is the second

Pagina 75 - The welcome window opens

5 Virtual-IO Manager user interfaceconfigured.By default, Activate Port Backup is selected.Linkdown propagationSend a linkdown event if both the activ

Pagina 76 - 4. Click Next

Auto negotiationThe transmission speed is negotiated with the external switch. Youcan achieve a transmission speed of 1 Gbit/s with this value.10 Mbit

Pagina 77 - 5. Click Next

5 Virtual-IO Manager user interfaceAssigns the port as a backup port to the uplink set. If the port isalready assigned to another uplink set, this ass

Pagina 78

Edit Properties step for dedicated service networksFigure 35: Create Network wizard (second step)Name of uplink setName of uplink set. In the case of

Pagina 79

Managed BX900 blade serversSupported systems: BX900 with MMB S1. For information on the requiredfirmware version, see the release notes supplied.The f

Pagina 80

5 Virtual-IO Manager user interfaceIf you select Linkdown propagation, the ports of the related serverblades receive a linkdown event if a problem occ

Pagina 81

100 Mbit/s100 Mbit/s full-duplex.By default, Auto negotiation is selected.Service VLAN idA Service VLAN ID must be specified.IGMP SnoopingIf IGMP Snoo

Pagina 82

5 Virtual-IO Manager user interfaceActiveOnly available if the port is configured as Backup.The corresponding port is configured as active and no long

Pagina 83

Figure 36: Create Network wizard (DCB Properties)Enable DCBEnables the DCB feature of the connection blade. The DCB (DataCenter Bridging) settings her

Pagina 84

5 Virtual-IO Manager user interfaceThis is the bandwidth reserved for the FCoE function.The FCoE function might share the complete bandwidthof 10 Gb w

Pagina 85 - [ -h

VLAN-IdThe unique VLAN number of the network specified above. The VLAN IDmust be assigned uniquely within a shared uplink set.Native VLANDefines a net

Pagina 86

5 Virtual-IO Manager user interfacein the same chassis that use the same network cannot communicatewith each other, but only with an external device t

Pagina 87

Edit Properties step for single networks/VLAN networksFigure 38: Edit Uplink Set wizard (first step)You can modify following parameters in the first s

Pagina 88

5 Virtual-IO Manager user interfacelinkdown event is then triggered if all ports configured as active and allports configured as backup ports of an up

Pagina 89

IGMP SnoopingIf IGMP Snooping is activated, the connection blade controls whetherrequests to join a multicast group occur at the downlink ports of an

Pagina 90 - 3.6 License management

1 IntroductionThe Virtual-IO Manager can only manage BX900 chassis with S1management blades (MMB S1) that are assembled with the fol-lowing:l In fabri

Pagina 91

5 Virtual-IO Manager user interfaceThe corresponding port is configured as a backup port and no longeras active port.Ports configured as active or bac

Pagina 92

Activate Port BackupSwitch to a backup port if an error occurs in the active port. The portbackup function is only available if at least one backup po

Pagina 93

5 Virtual-IO Manager user interfacevalue if a problem occurs using the drop-down menu according to the set-tings on the external switch. The following

Pagina 94

Assigns the port as a backup port to the uplink set. If the port isalready assigned to another uplink set, this assignment is deleted.RemoveOnly avail

Pagina 95 - CREATE DATABASE ViomDB

5 Virtual-IO Manager user interfaceFigure 40: DCB PropertiesEnable DCBEnables the DCB feature of the connection blade. The DCB (DataCenter Bridging) s

Pagina 96

internally adjusted accordingly.This is the bandwidth reserved for the FCoE function.The FCoE function might share the complete bandwidthof 10 Gb with

Pagina 97 - 4 Configuration

5 Virtual-IO Manager user interfaceAdd another networkNetwork Namemeaningful name of the network.VLAN IdThe unique VLAN number of the network specifie

Pagina 98

Service VLANSelect the checkbox in the corresponding row under Service VLAN inthe table to define a network as a service VLAN.Isolate modeSelect the c

Pagina 99

5 Virtual-IO Manager user interfaceFigure 42: Name stepName of the profileName of the server profile. If a profile already exists with this name orthe

Pagina 100

The number and type of LAN ports under Onboard IO channels areadjusted automatically according to the server model you select. Thenumber of LAN ports

Pagina 101

Managed PRIMERGY rack servers und PRIMERGY tower serversThe following PRIMERGY rack and tower server models are supported:PRIMERGYmodelScope of functi

Pagina 102

5 Virtual-IO Manager user interfaceDepending on the selected profile and server type, there are a number ofboxes, each representing a slot for a mezza

Pagina 103

Figure 44: IO-Channels stepLocal boot settings usedThis message shows that the local boot settings are being used in theserver profile. This message i

Pagina 104 - 4.1.4 Connecting IBP modules

5 Virtual-IO Manager user interfaceFabric 3All paths are routed to fabric 3.Fabric 4All paths are routed to fabric 4.Fabric 3 & 4LAN1 is routed to

Pagina 105

Column SignificanceNetwork Name of the network. You can specify a network for each LAN orCNA port, but not for profiles of type Rack Server.If you wan

Pagina 106

5 Virtual-IO Manager user interfaceColumn SignificanceService Names of the service networks. You can specify service net-works for each LAN or CNA por

Pagina 107

Boot Parameters for an iSCSI boot (LAN ports or iSCSI function onCNA mezzanine card)Figure 45: Boot Parameter step (iSCSI boot)Initiator ParametersAdd

Pagina 108

5 Virtual-IO Manager user interfaceVLAN IdVLAN ID that is used by the HBA to send its requests.(optional)Should be used only for CNA-iSCSI-functions.I

Pagina 109

Target NameIQN name of the iSCSI target. You can enter a name in this field ifAddress Origin: static is selected.IPv4 addressIP address of the iSCSI t

Pagina 110

5 Virtual-IO Manager user interfaceChap SecretCHAP password. This password must be identical to the password con-figured on the iSCSI target. It must

Pagina 111

Port NameWWPN (worldwide port name) of the port for the boot device.LUNLUN (logical unit number) address of the boot device. The default valuefor the

Pagina 112

Comments… Suggestions… Corrections…The User Documentation Department would like to know your opinion ofthis manual. Your feedback helps us optimize ou

Pagina 113

1 IntroductionPCI controller Scope of functionsEmulex 10GbE OCe10102CNADefine physical functions and type (LAN,FCoE, iSCSI) of physical functions.Assi

Pagina 114

5 Virtual-IO Manager user interface8 Gbit/s8 Gbit/s full-duplexTopologyType of port connection with the external SAN network. Possible values:auto (lo

Pagina 115 - 4.2.4 Connecting IBP modules

Figure 47: CNA Parameter stepBandwidthThe share of the bandwidth in percent that is assigned to this function. Ifthe sum of all bandwidths of one IO-c

Pagina 116

5 Virtual-IO Manager user interfaceEnable DCB SettingsThis option is available only for FCoE and iSCSI functions. It enablesthe DCB (Data Center Bridg

Pagina 117 - 4.2.5 Switch stacking support

Figure 48: Virtual Addresses stepVirtual MAC, Virtual WWNN, Virtual WWPN, Virtual E-MACThe virtual address. Virtual MAC and E-MAC (Enode MAC) addresse

Pagina 118

5 Virtual-IO Manager user interfaceNext to each virtual address, you see the status of the address. The statuscan have the following values:Status Sig

Pagina 119

Figure 49: Confirm step5.4.4 Edit Server Profile wizardYou use this wizard to modify a server profile.The Edit Server Profile wizard comprises several

Pagina 120

5 Virtual-IO Manager user interfaceFigure 50: Name stepName of the profileName of the server profile. If a profile already exists with this name orthe

Pagina 121

The number and type of LAN ports under Onboard IO channels areadjusted automatically according to the server model you select. Thenumber of LAN ports

Pagina 122

5 Virtual-IO Manager user interfaceDepending on the selected profile and server type, there are a number ofboxes, each representing a slot for a mezza

Pagina 123

Figure 52: IO-Channels stepLocal boot settings usedThis message shows that the local boot settings are being used in theserver profile. This message i

Pagina 124

For information on the required firmware version, see the release notes sup-plied.1.4 Changes since the previous editionThe current edition is valid f

Pagina 125

5 Virtual-IO Manager user interfaceFabric 3All paths are routed to fabric 3.Fabric 4All paths are routed to fabric 4.Fabric 3 & 4LAN1 is routed to

Pagina 126 - 4.3.4 Connecting IBP modules

Column SignificanceNetwork Name of the network. You can specify a network for each LAN orCNA port, but not for profiles of type Rack Server.If you wan

Pagina 127 - 4.3.5 Switch stacking support

5 Virtual-IO Manager user interfaceColumn SignificanceService Names of the service networks. You can specify service net-works for each LAN or CNA por

Pagina 128

Boot Parameters for an iSCSI boot (LAN ports) or iSCSI function onCNA mezzanine cardFigure 53: Boot Parameter step (iSCSI boot)Initiator ParametersAdd

Pagina 129

5 Virtual-IO Manager user interfaceIPv4 addressStatic client IP address to be used for this port. The port will use this IPaddress for the entire iSCS

Pagina 130

IPv4 addressIP address of the iSCSI target. You can enter an IP address in this field ifAddress Origin: static is selected.PortTCP port number (defaul

Pagina 131

5 Virtual-IO Manager user interfaceThis password must differ from the password in the Mutual ChapSecret field.Mutual Chap SecretThe mutual CHAP passwo

Pagina 132

LUNLUN (logical unit number) address of the boot device. The default valuefor the field is 0.2nd TargetIn 2nd Target, you configure the backup boot de

Pagina 133

5 Virtual-IO Manager user interfaceTopologyType of port connection with the external SAN network. Possible values:auto (loop first)auto (Point-to-Poin

Pagina 134

Figure 55: CNA Parameter stepEnable DCB SettingsThis option is available only for FCoE and iSCSI functions. It enablesthe DCB (Data Center Bridging) f

Pagina 135

1 IntroductionFor ServerView Suite, links are offered on the following topics:l Foruml Service Deskl Manualsl Product informationl Security informatio

Pagina 136

5 Virtual-IO Manager user interfaceBandwidthThe share of the bandwidth in percent that is assigned to this function. Ifthe sum of all bandwidths of on

Pagina 137 - Figure 22: VIOM main window

Virtual MAC, Virtual WWNN, Virtual WWPN, Virtual E-MACThe virtual address. Virtual MAC and E-MAC (Enode MAC) addressesmust have the structure xx:xx:xx

Pagina 138

5 Virtual-IO Manager user interfaceStatus SignificanceOut of range(error)The address is outside the specified address range.Syntax error(error)The add

Pagina 139 - 5.2 Tree view

5.4.5 Save Configuration wizardYou use the Save Configuration wizard to save and to restore backup filesas well as to delete them on the management st

Pagina 140

5 Virtual-IO Manager user interfaceRestore ConfigurationSelect Restore Configuration to restore a configuration from a file.Delete ConfigurationSelect

Pagina 141

Column SignificanceDate Date and time when the backup file iscreated.You can sort the list of existing backup files according to file name ordate by c

Pagina 142 - 5.3 Tabs

5 Virtual-IO Manager user interfaceFigure 60: Select File step (Restore Configuration wizard)Restore file from Management StationBackup file from the

Pagina 143

BrowseOpens the file selection dialog box in which you can select the rel-evant backup file.5.4.5.4 Select File step (Delete Backup Files wizard)Selec

Pagina 144 - 5.3.2 Setup tab

5 Virtual-IO Manager user interfaceClear SelectionDeselects all the backup files.5.4.5.5 Select Data step (Save Configuration wizard)Select Data is th

Pagina 145

5.4.5.6 Select Data step (Restore Configuration wizard)Select Data is the third step in the Restore Configuration wizard. In thisstep you define the d

Pagina 146

l Select Help – Links on the start page or on the menu bar.This opens the start page of the ServerView link collection.2. Via the ServerView Suite DVD

Pagina 147

5 Virtual-IO Manager user interfaceThe Restore Options dialog box opens automatically in which youspecify additional parameters (see section "Res

Pagina 148

In this step you will see the names of the files you wish to delete. The filesare deleted after you have clicked Finish.5.5 Dialog boxesVirtual-IO Man

Pagina 149

5 Virtual-IO Manager user interfaceFigure 65: VIOM Manager authentication (single blade server)In this dialog box, you enter the user names/passwords

Pagina 150

For security reasons you should change the default user name and passwordcombination. You can have the same user name and password for all com-ponents

Pagina 151

5 Virtual-IO Manager user interfaceFor a standard configuration, these values should not bechanged.5.5.2 Authentication dialog box (PRIMERGY rack serv

Pagina 152

ponents or different ones for each. You must specify this accordingly in thisdialog box.With the Configure protocols button you can expand the dialog

Pagina 153

5 Virtual-IO Manager user interfaceUse default portUses the default port. The default port is dependent on the protocol andthe relevant module.For a P

Pagina 154

User nameA valid user name with access rights to the MMBs, IBPs, and iRMCsPasswordPassword of the user ID5.5.4 Licenses Information dialog boxThe Lice

Pagina 155

5 Virtual-IO Manager user interfaceAssign LimitMaximum number of server profiles that can be assigned with thelicensesUsed AssignsNumber of server pro

Pagina 156

Display tabFigure 69: Display tab (Preferences dialog box)The Display tab allows you to reset the display settings. If you change somedisplay properti

Pagina 157

1 Introduction1.7 Typographic conventionsThe following typographic conventions are used:Convention ExplanationIndicates various types of risk, namely

Pagina 158 - 5.3.6 Server Profiles view

5 Virtual-IO Manager user interfaceTrace tabFigure 70: Trace tab (Preferences dialog box)On the Trace tab, parameters for tracing the VIOM-GUI can be

Pagina 159

If the maximum file size is reached, the trace file will be renamed and anew one will be used. The renamed trace files will have a number append-ed, u

Pagina 160

5 Virtual-IO Manager user interfaceFor PRIMERGY rack servers, the Restore Options dialog box canalso be opened by clicking the Options... button. But

Pagina 161 - 5.4 Wizards

dialog box where you can select the destination blade server.OKApplies your selection and closes the dialog box.CancelCloses the dialog box without ap

Pagina 162

5 Virtual-IO Manager user interfaceRestore only reassigned profilesSpecifies that only the profiles that are reassigned to the selected bladeservers w

Pagina 163

This will be necessary if address ranges have been changed since thebackup configuration has been saved or if it is created on another man-agement sta

Pagina 164

5 Virtual-IO Manager user interfaceFigure 73: Select Profile dialog boxPower On after AssignThe server is started once the server profile has been ass

Pagina 165

Ignore SpareNo warning during assignment to a spare slotSkip downlink checksNo warning, even though ports are configured in the server profile forwhic

Pagina 166

5 Virtual-IO Manager user interfaceNew Uplink SetDefine a new uplink setEdit Uplink SetEdit an uplink setDeleteDelete network(s) or uplink set(s)The c

Pagina 167

New ProfileCreate a server profileThe context menu of a profile contains the following menu items:Edit ProfileEdit selected server profileShow Profile

Pagina 168

2 Virtual-IO Manager - IntroductionThis chapter provides a general introduction to the concept of the Virtual-IOManager (VIOM).2.1 Virtual addressesPh

Pagina 169

5 Virtual-IO Manager user interfaceInventory BootRe-create the inventory table of the server.During inventory boot the system BIOS assembles the inven

Pagina 170

5.7 General buttonsThis section describes the general buttons that you will come across in theVirtual-IO Manager.5.7.1 Buttons in the area on the left

Pagina 171

5 Virtual-IO Manager user interfaceHelp buttonClick Help to launch the context-sensitive online help.Next buttonClick Next to go to the next step of t

Pagina 172

6 Using the Virtual-IO Manager6.1 Starting the Virtual-IO ManagerYou can start the Virtual-IO Manager from the main window of the Server-View Operatio

Pagina 173

6 Using the Virtual-IO Manager6.3 Logging the actions using VIOM6.3.1 Logging the actions on WindowsThe Virtual-IO Manager logs all actions in the Win

Pagina 174

Figure 74: VIOM-specific log fileServerView Virtual-IO Manager 2556.3 Logging the actions using VIOM

Pagina 175

6 Using the Virtual-IO Manager6.3.2 Logging the actions on LinuxOn Linux the actions of VIOM are logged using the Syslog mechanism. Allinformational m

Pagina 176 - 5.4.2 Edit Uplink Set wizard

7 Managing servers with VIOMWhen you install a new server that can be managed using VIOM and add it tothe ServerView server list, then this server is

Pagina 177

7 Managing servers with VIOMTo manage a blade server, you have to access the management blade of theBX600/BX400/BX900 chassis and the IBP modules in t

Pagina 178

password for the management blade or the first PRIMERGY rack serverand click Use for all components. These settings are then applied toall I/O connect

Pagina 179

2 Virtual-IO Manager - IntroductionFigure 1: Overlapping areas of responsibilityAs the areas of responsibility overlap, this means that up to three ad

Pagina 180

7 Managing servers with VIOM2. Click Authentication on the Setup tab. The Authentication dialog boxopens. See "Authentication dialog box (single

Pagina 181

7.3 Deactivating management with VIOMYou deactivate the management of servers by moving the servers from theVIOM Managed server group to the VIOM Mana

Pagina 182

7 Managing servers with VIOM1. The chassis is indicated as "managed". This happens, on the one hand,in the VIOM database. However, informati

Pagina 183

Standard configuration before activating VIOM managementFigure 75: Standard configuration of the IBP 10/6 before activationIn this configuration, all

Pagina 184 - Figure 40: DCB Properties

7 Managing servers with VIOMInitial configuration after activating VIOM managementFigure 76: Initial configuration of the IBP 10/6 after activationAft

Pagina 185

configured so that they can be accessed from the central managementstation via their management port.3. In the management blade, any existing virtuali

Pagina 186

7 Managing servers with VIOM7.5 VIOM-internal operations on a PRIMERGYrackserverThis section explains the internal operations perfomed when you activ

Pagina 187

The iRMC has limited storage to store multiple trap des-tinations. This configuration can be modified by other programsor by using the iRMC user inter

Pagina 188 - Figure 42: Name step

7 Managing servers with VIOMsupport this functionality.4. VIOM performs a special so-called init boot that initializes all the I/Odevices with the vir

Pagina 189

addresses or WWN addresses) are used from now on. Also the bootdevice priority setting as defined in the VIOM server profile is no longervalid. The pe

Pagina 190

To resolve these problems, the switch blades installed in the blade servercan be replaced by special connection blades. The following connectionblade

Pagina 191 - Figure 44: IO-Channels step

7 Managing servers with VIOMstation indicating that it is still waiting for these data. This process can beinterrupted by disabling the VIOM managed s

Pagina 192

To deactivate the server’s VIOM-managed status in the iRMC user interface,click the Disable VIOM button in the iRMC view System Overview.To deactivate

Pagina 193

7 Managing servers with VIOMSelect VIOM in the Advanced menu and set the VIOM-flag from Enabled toDisabled:272 ServerView Virtual-IO Manager

Pagina 194

Regardless of whether you deactivate the VIOM-managed status via theiRMC interface or via the BIOS interface, the VIOM-enabled flag is reset, andthe i

Pagina 195

7 Managing servers with VIOMVIOM-internal operations during deactivationWhen you deactivate management with the Virtual-IO Manager for a PRIM-ERGY rac

Pagina 196

7.6 Displaying license informationYou use the Show Licenses button on the Virtual-IO Manager tab torequest information on the licenses assigned.1. To

Pagina 197

276 ServerView Virtual-IO Manager

Pagina 198

8 Defining network paths (LAN)This chapter describes how to define network paths on an IBP module (LANconnection blade) using VIOM.In the Virtual-IO M

Pagina 199

8 Defining network paths (LAN)The Chassis Configuration tab provides an overview of the configuration(IBP configuration and server profile assignment)

Pagina 200

out what other entries you need to make during the further course ofthe wizard, see section "Defining a dedicated service network" onpage 28

Pagina 201 - Figure 47: CNA Parameter step

2 Virtual-IO Manager - IntroductionFigure 2: Separate areas of responsibility2.3 Management with VIOM - ProcedureYou use the ServerView Virtual-IO Man

Pagina 202

8 Defining network paths (LAN)8.1.2 Defining a single networkIn VIOM, a single network refers to a network in which a server blade cancommunicate exte

Pagina 203

3. In the first step of the Create network wizard, select Single networkand confirm your entry by clicking Next. The second step of the Createnetwork

Pagina 204

8 Defining network paths (LAN)7. If the uplink set is created on a PY CB Eth Switch/IBP 10 Gb 18/8, clickNext to confirm your entries. The next step o

Pagina 205 - Figure 49: Confirm step

3. In the first step of the Create network wizard, select VLAN / ServiceVLAN networks and confirm your entry by clicking Next. The secondstep of the C

Pagina 206 - Figure 50: Name step

8 Defining network paths (LAN)works defined via VLAN IDs, which are to be assigned to the uplink setdefined in the previous step.8. Enter the meaningf

Pagina 207

For further information on defining networks, see section "Defining networks(LAN) (for blade servers only)" on page 30.8.1.4 Defining a dedi

Pagina 208

8 Defining network paths (LAN)The name of the uplink set cannot be changed; the field is inac-tive. The type of the uplink set cannot be changed eithe

Pagina 209 - Figure 52: IO-Channels step

A message appears asking whether you wish to delete the cor-responding network.3. If you confirm this, the networks will be deleted.If you delete all

Pagina 210

8 Defining network paths (LAN)l VIOM always copies the entire configuration irrespective ofwhat is selected in the tables.l If the target IBP has fewe

Pagina 211

9 Defining and assigning server profilesTo use address virtualization or to enable a server blade to use a defined net-work, you must:1. Define a serv

Pagina 212

For blade servers, management with VIOM essentially includes the followingfunctions:l Defining the network paths on the Intelligent Blade Panel (IBP m

Pagina 213

9 Defining and assigning server profilesAn overview of the defined server profiles is displayed via the profile view onthe left of the ServerView Virt

Pagina 214

5. Once you have entered all the required data, click Next to go to the Con-figure Cards step of the wizard.6. Select the type and number of onboard I

Pagina 215

9 Defining and assigning server profilesIf you want to use the profile on blade servers with IBP modules,you can specify a network for each LAN port.

Pagina 216

iSCSI boot device or SAN boot device, you must specify additional bootsettings in the next step.15. Click Next to access another step in this wizard.

Pagina 217

9 Defining and assigning server profiles19. Once you have entered all the required data, click Next to go to the Con-firm step of the wizard.20. Use t

Pagina 218

2. Select the required profile in the area on the right of the ServerView Vir-tual-IO Manager window. Then click Edit or select Edit Profile fromconte

Pagina 219 - Figure 55: CNA Parameter step

9 Defining and assigning server profilesYou can only copy server profiles if you specified address ranges forthe virtual addressed when you installed

Pagina 220

2. In the tree structure on the left, select the corresponding blade server orPRIMERGY rack server from the VIOM Managed group.3. Switch to the Server

Pagina 221

9 Defining and assigning server profiles8. Confirm your selection with OK. The selected server profile is assignedto the slot.If you have not selected

Pagina 222 - Figure 57: Confirm step

5. You can only deactivate a server profile if the corresponding server isswitched off (power off). You can see whether the server is switched offin t

Pagina 223 - Figure 58: Select Action step

ContentsContents 31 Introduction 111.1 Target groups and objective of this manual 121.2 System requirements 121.3 Supported Hardware 141.4 Changes sin

Pagina 224

2 Virtual-IO Manager - Introduction4. You can then assign these server profiles to any of the individual slots ofa blade server or to a PRIMERGY rack

Pagina 225

300 ServerView Virtual-IO Manager

Pagina 226

10 Viewing the blade server con-figurationYou view the blade server configuration via the Chassis configuration tab.1. Click the Chassis configuration

Pagina 227

302 ServerView Virtual-IO Manager

Pagina 228

11 Saving and restoringYou can save your blade server configuration and server profiles in files andrestore them later. Backups like these are useful,

Pagina 229

11 Saving and restoringl Select an existing file from the list that will then be overwritten.l Enter the name for the backup file directly in the inpu

Pagina 230

3. Click Next to go to the Select File step.4. Select the backup file from which you want to restore the configuration:l Select Restore file from Mana

Pagina 231 - 5.5 Dialog boxes

11 Saving and restoring3. Select the Keep existing profiles option, to keep the existing profiles.This option is selected automatically if you select

Pagina 232

by clicking the Options... button in the table row.2. Select Restore Spare Information to restore the information on thespare slots.3. Select Reassign

Pagina 233

11 Saving and restoring11.3 Deleting backup files on the management stationThe starting point for deleting backup files on the management station is t

Pagina 234

The Restore IBP function rewrites the configuration saved internally in theVIOM database to the IBP module.In doing so, all the connections are interr

Pagina 235

If a blade server chassis is managed by VIOM, manual con-figurations (not done by VIOM) of an IBP connection blade are notsupported. Manual configurat

Pagina 236

11 Saving and restoringDelete Configuration deletes the configuration saved internally in the VIOMdatabase.11.4.3 Restoring the configuration of a ser

Pagina 237

11.4.4 Restoring the blade server chassis configurationBy clicking Restore on the Setup tab, the entire virtualization information ofthe Virtual-IO Ma

Pagina 238 - 5.5.5 Preferences dialog box

312 ServerView Virtual-IO Manager

Pagina 239

12 Importing and exporting server pro-filesYou have the option of exporting and importing server profiles. The exporteddata is available as XML files

Pagina 240

12 Importing and exporting server profiles12.3 Format of export filesThe file specified during an import must be an XML file whose root element isObje

Pagina 241

The Objects element contains the following elements:l UserInfo (optional)l ServerProfiles Describes the profiles to be imported (see below)12.3.2 The

Pagina 242

12 Importing and exporting server profilesexistingAddressActionSpecifies the response if a virtual address is already in use. For individ-ual server p

Pagina 243

ContinueErrors are converted into warnings and the import then continueswith the next object.existingProfileActionoptionalSpecifies the response if a

Pagina 244

12 Importing and exporting server profilesServerProfileNameName of the server profile.IOVirtualizationUsageYesThe profile uses virtual addresses. You

Pagina 245

Fabric4DefaultAll paths are routed to fabric 4.Fabric3+4LAN1 is routed to fabric 3 and LAN2 to fabric 4.IOChannelsDefines the ports. This element cont

Pagina 246

2 Virtual-IO Manager - IntroductionIn the case of IBP 30/12, the first 8 uplink ports are combined in oneuplink set by default, and all 30 downlinks a

Pagina 247 - 5.6 Context menus

12 Importing and exporting server profilesISCSIFunctionPhysical iSCSI function of a CNA portIOSlotIndexFor I/O Channels in a profile that uses only on

Pagina 248

NetworksDefines the networks used by this IO channel. This element contains anoptional NetworkName element optionally followed by one or moreServiceNa

Pagina 249

12 Importing and exporting server profilesBootDeviceUsageIndicates whether the port is used as a boot device.YesThe port is a boot device and the Boot

Pagina 250

FunctionConfigurationoptionalSpecifies the configuration for a function (see " The Func-tionConfiguration element" on page 329). This elemen

Pagina 251 - 5.7 General buttons

12 Importing and exporting server profilesl FCBootConfigurationBootPrioritySpecifies the boot order. Possible values are 1 to 4. However, eachvalue ca

Pagina 252 - 5.8 Icons

NoA static client IP address, subnet mask, and gateway IPaddress must be specified.NameName of the iSCSI initiator to be used (in the case of an iSCSI

Pagina 253

12 Importing and exporting server profilesDHCPUsageYesIn the case of an iSCSI boot, the system tries to obtain thename of the iSCSI target, the IP add

Pagina 254

CHAPCHAP authentication is activated for this port. CHAP allowsthe target to authenticate the initiator.MutualCHAPMutual CHAP authentication is activa

Pagina 255

12 Importing and exporting server profilesThe first or only FCTarget configures the boot device while the secondFCTarget configures the backup boot de

Pagina 256

4Point-to-Point8auto (Point-to-Point first)12Arbitrated loop12.3.9 The DCBConfiguration elementThe DCBConfiguration element specifies one priority gro

Pagina 257 - 7 Managing servers with VIOM

Figure 4: Typical uplink setsThe uplink ports can be assigned to an uplink set as active ports or as back-up ports. As a result, there are different w

Pagina 258

330 ServerView Virtual-IO Manager

Pagina 259

13 VIOM scenariosThis chapter describes examples of when VIOM can be used.13.1 Shifting tasks from one server blade to anotherIf an operating system o

Pagina 260

13 VIOM scenarios5. You can only assign a server profile to a server blade if the server bladeis shut down.Therefore shut the server blade down, if ap

Pagina 261

4. Define the slots that are to be available as spare slots for a server profilefailover. To do this, enable the check box in the Spare column in thet

Pagina 262

13 VIOM scenariosThis means you shut down the blade on the failed site, unassign the profile,and assign it again on the other site. But this only work

Pagina 263

To allow the switchover in this case, VIOM provides a “forced unassign”option, allowing you to unassign a profile even if the corresponding MMB (con-t

Pagina 264

13 VIOM scenariosVia iRMC on each server blade:As an alternative you may log on to each iRMC and set the “Power RestorePolicy” to “Always power off” f

Pagina 265

14 VIOM databaseThis chapter describes the VIOM database on a Windows- or Linux-basedCMS.The Virtual-IO Manager requires two databases:l The ServerVie

Pagina 266

14 VIOM database"Installing ServerView Operations Manager Software under Linux - Instal-lation Guide".14.1 VIOM Backup ServiceThe Backup Ser

Pagina 267

The following parameters need to be configured for the backup jobs:l The Quartz cron expressions which determine when the backup jobs arescheduled (se

Pagina 268

2 Virtual-IO Manager - Introductionaggregation group (LAG) is formed. By providing several parallel con-nections, you achieve higher level of availabi

Pagina 269 - Behavior after AC failure

14 VIOM databaseTrigger description relating to the full backup job in the quartz_jobs.xml file<trigger><cron><name>cronFullBacku

Pagina 270

Field Mandatory Values Special charactersMonth yes 1 - 12 or JAN - DEC , - * /Day of Week yes 1 - 7 or SUN - SAT , - * / ? L #Year no 1970 - 2099 , -

Pagina 271

14 VIOM databaseSpecialcharactersDescription Example Meaning ofthe example? Day of month and day ofweek must not be given avalue at the same time, sou

Pagina 272 - Disabled:

For PostgreSQL:If the schedule does not suit your needs, you should edit theQuartz cron expression:<cron><name>PostgresJobTrigger</name

Pagina 273

14 VIOM databasel The outputDirLinux entity defines the directory for full backup files(example: /var/fujitsu/ServerViewSuite/viom/postgres/backups) o

Pagina 274

14.1.6 Logging the Backup ServiceThe Backup Service logs important events in the Windows Event Logging orsyslog on Linux.So you can search the Windows

Pagina 275

14 VIOM databaseStop the services ServerView Virtual IO Manager Services and Server-View Virtual IO DB Backup Services:1. Select Start – [Settings] –

Pagina 276

2. On the General page, enter the name ViomDB or master in the To data-base field or select the name from the list.3. Select the option From device.4.

Pagina 277

14 VIOM database10. Click OK and then OK again.Restoration of the database begins. In the ObjectExplorer you will see themessage ViomDB (Restoring…).R

Pagina 278 - 8.1 Defining an uplink set

1. Select Start – [Settings] – Control Panel – Administrative Tools –Services.2. Select the appropriate service and then select Restart from the conte

Pagina 279

A key attribute of a "single" network is that it is VLAN transparent. You cantherefore channel several external networks with different VLAN

Pagina 280

14 VIOM databaseMake all other entries as described in the relevant sections. Afterwards, thedatabase should have been restored under the name RECOVER

Pagina 281

5. Start the VIOM Backup Service:/etc/init.d/viom_backup startServerView Virtual-IO Manager 35114.3 Restoring the VIOM database on Linux

Pagina 282 - 8.1.3 Defining VLAN networks

352 ServerView Virtual-IO Manager

Pagina 283

15 Appendix15.1 Replacing IBP modulesIf an IBP connection blade in a chassis managed by Virtual-IO Manager fails,please perform the following actions

Pagina 284

15 Appendixusing telnet as the communication protocol, please check whether telnetis enabled on the new connection blade.5. When the new connection bl

Pagina 285 - 8.2 Modifying an uplink set

These address ranges are defined as follows:Address range Start address End addressMAC1 00:19:99:3E:D2:A1 00:19:99:3E:F1:E0MAC2 00:19:99:3E:F1:E1 00:1

Pagina 286 - 8.3 Deleting networks

15 AppendixThese address ranges are defined as follows:Address range Start address End addressWWN1 50:01:99:93:ED:2A:10:00 50:01:99:93:EF:1E:0D:FFWWN2

Pagina 287

On a Windows operating system this is typically the directory C:\ProgramFiles\Fujitsu\ServerView Suite\plugins\viom\Manager.Please modify the line Sta

Pagina 288 - 8.5 Copying configuration

15 AppendixAfter modifying the StartOptions property in the Viom-Config.properties file or the MaxBackupIndex property in theman-log4j.properties file

Pagina 289

For how to collect diagnostic data on a Linux operating system, see the chap-ter "Collecting diagnostic information" on page 89.To activate

Pagina 290 - 9.1 Defining server profiles

2 Virtual-IO Manager - IntroductionFigure 5: Networks with VLAN IDIn the figure above, two shared uplink sets are configured on the IBP module.Two vir

Pagina 291

15 Appendixl For LinuxVirtual-IO Manager events are output to the system log with sourceVIOM-MAN, VIOM-LICENSE-MANAGER, and VIOM-BACKUP-SERVICE.The ev

Pagina 292

EventIDMeaning50722 Profile modified.50723 Profile deleted.50735 Profile assigned.50736 Profile unassigned.50821 IO-channel added to profile.50822 IO-

Pagina 293

362 ServerView Virtual-IO Manager

Pagina 294 - 9.3 Modifying server profiles

Packets that come from outside the network with no VLAN tag are alsodropped. This behavior can be changed by configuring a virtual network asnative VL

Pagina 295 - 9.4 Copying server profiles

2 Virtual-IO Manager - IntroductionFigure 6: Networks with a VLAN ID and a native VLAN IDIn the figure above, the VLAN ID 10 is defined as the native

Pagina 296 - 9.6 Assigning server profiles

Figure 7: Virtual networks with VLAN ID used in tagged modeSeveral VLAN networks in tagged mode can be used on the same IBP down-link port. They can a

Pagina 297

Contents3.5 Updating the Virtual-IO Manager on a Linux-based CMS 893.6 License management 903.7 Updating ServerView Operations Manager 943.8 Upgrading

Pagina 298

2 Virtual-IO Manager - IntroductionDedicated service networksFigure 8: Dedicated service networksThe dedicated service network is designed to separate

Pagina 299

The same VLAN tag must be specified when defining the dedicated servicenetwork that is to transport these packages.The behavior of a dedicated service

Pagina 300

2 Virtual-IO Manager - IntroductionService VLAN networksFigure 9: Service VLAN networksThe Service VLAN networks are designed to separate LAN packages

Pagina 301

Note that Service VLAN networks may overlap on the downlink ports (withsingle networks, VLAN networks, dedicated service networks and other Serv-ice V

Pagina 302

2 Virtual-IO Manager - Introductiona server profile failover, which searches for a suitable spare server blade thatwill assume the tasks of the failed

Pagina 303 - 11 Saving and restoring

2.5.3 Dedicated LAN connections (only for blade servers)You can assign each I/O port of a server blade to an explicit network in theserver profile. As

Pagina 304

2 Virtual-IO Manager - IntroductionBlade ServersThe virtualization I/O parameters of all the server blades of a chassis arestored in a specific table

Pagina 305

If the virtualization of the I/O addresses for a slot is switched off, e. g. if thecorresponding server profile is unassigned, the physical I/O addres

Pagina 306

2 Virtual-IO Manager - Introduction2.7 High-Availability (HA) supportVIOM supports the following high-availability environment:l Windows 2008 R2 Hyper

Pagina 307

Operating system Admin server if HAGuestOSHypervisorWindows Server 2008 R2 Foundation [*]PP[Hyper-V]Windows Server 2008 Standard (x86, x64) [*]PP[Hype

Pagina 308

4.3.4 Connecting IBP modules 1264.3.4.1 Network - Overview 1264.3.5 Switch stacking support 1274.4 Configurations on the managed PRIMERGY rack server

Pagina 309

2 Virtual-IO Manager - IntroductionFigure 11: Failover action of the Hyper-V environment to the other cluster nodeIn the failover clustering of the Hy

Pagina 310

12. Install and configure ServerView Operations Manager and ServerViewVirtual-IO Manager.On the secondary node:1. Connect with shared storage.2. Confi

Pagina 311

2 Virtual-IO Manager - IntroductionFigure 12: Architecture and typical configuration of VMware Infrastructure 352 ServerView Virtual-IO Manager

Pagina 312

Figure 13: Host failover with VMware HAVMware HA links up multiple ESX/ESXi servers to form a cluster withshared resources. If one host fails, VMware

Pagina 313

2 Virtual-IO Manager - IntroductionThe details of this configuration cannot be seen via the nor-mal graphical user interface of the service manager. T

Pagina 314 - 12.3 Format of export files

ice has restarted, the configuration should be the same as it was justbefore the interrupted request.Some configuration actions of the Virtual-IO Mana

Pagina 315

56 ServerView Virtual-IO Manager

Pagina 316

3 Installation and uninstallationYou can install the Virtual-IO Manager on a central management station(CMS) under Windows or Linux (see section "

Pagina 317

3 Installation and uninstallationIn Japan: Novell SLES is not supported.ServerView Virtual-IO Manager can also be installed in Virtual Machine(VM) und

Pagina 318

3.2.1 Installing the Virtual-IO Manager using a graphical inter-faceInstallation process1. Insert the PRIMERGY ServerView Suite DVD 1 in the DVD-ROM d

Pagina 319 - 12.3.4 The IOChannel element

Contents5.4.2.2 Edit Properties step (Edit Uplink Set wizard - dedicatedservice network) 1805.4.2.3 DCB Properties (Edit Uplink Set wizard - single/VL

Pagina 320

3 Installation and uninstallation7. Click Next.Accept the license agreement by selecting the corresponding option.60 ServerView Virtual-IO Manager

Pagina 321

8. Click Next.Enter your name and the name of your company/organization. You mustalso specify whether the settings should only apply for the current u

Pagina 322

3 Installation and uninstallation9. Click Next.If you select Select address ranges for IO Virtualization, you canspecify address ranges for virtual ad

Pagina 323 - 12.3.5 The Address element

In this window, specify which address range the Virtual-IO Managershould use for virtual MAC addresses. The virtual MAC addresses areassigned automati

Pagina 324

3 Installation and uninstallationThe validity of the MAC address input is not checked. Pleaseconfirm that your input address is valid before you click

Pagina 325

In this window, specify which address range the Virtual-IO Managershould use for virtual WWN addresses. The virtual WWN addresses areassigned automati

Pagina 326

3 Installation and uninstallation12. Click Next.Once you have made all your entries, click Next to start the installation.If you want to make further

Pagina 327

13. Click Next. The installation of the Virtual-IO Manager is started. The fol-lowing window is then displayed:14. Click Next to launch the License Ma

Pagina 328

3 Installation and uninstallation15. Click Register new license.Enter at least one valid license here so that you can use the Virtual-IOManager functi

Pagina 329

end>"][DEBUG_MODE=true|false][VIOM_LICENSE_KEY = "<key_value>"]Command line parameters for installation:DO_ADDRESS_RANGE_SELEC

Pagina 330

5.5.5 Preferences dialog box 2385.5.6 Restore Options dialog box (servers) 2415.5.7 Restore Options dialog box (server profiles) 2435.5.8 Select Profi

Pagina 331 - 13 VIOM scenarios

3 Installation and uninstallationMAC8Range 00:19:99:3F:AD:61 - 00:19:99:3F:CC:A1MAC12Range 00:19:99:3E:D2:A1 - 00:19:99:3F:11:20MAC34Range 00:19:99:3F

Pagina 332

WWN3Range 50:01:99:93:F1:12:0C:00 - 50:01:99:93:F3:06:09:FFWWN4Range 50:01:99:93:F3:06:0A:00 - 50:01:99:93:F4:FA:07:FFWWN5Range 50:01:99:93:F4:FA:08:0

Pagina 333 - 13.3 Disaster Recovery

3 Installation and uninstallationExample1.SV_VIOM.exe /q MAC_RANGE=MAC_CUSTOM MAC_START="11:22:33:44:55:66" MAC_END="22:33:44:55:66:77&

Pagina 334

Once the update installation is complete, the final window of the installationwizard confirms that the update installation has been successful, just l

Pagina 335

3 Installation and uninstallation3.4.1 Installing the Virtual-IO Manager using a graphical inter-faceIf you want to use the graphical installation, an

Pagina 336

3. After these preparations, start the installation by launching the GUI:sh install_viom.shThe welcome window opens.ServerView Virtual-IO Manager 753.

Pagina 337 - 14 VIOM database

3 Installation and uninstallation4. Click Next.Accept the license agreement by selecting the corresponding option.76 ServerView Virtual-IO Manager

Pagina 338 - 14.1 VIOM Backup Service

5. Click Next.Enter your name and the name of your company/organization.ServerView Virtual-IO Manager 773.4 Installing the Virtual-IO Manager on a Lin

Pagina 339

3 Installation and uninstallation6. Click Next.Enter the data on the ServerView database. The database user svuserhas been created during ServerView i

Pagina 340

7. Click Next.If you select Select address ranges for IO Virtualization, you canspecify address ranges for virtual addressing.If you want to use the a

Pagina 341

Contents8.2 Modifying an uplink set 2858.3 Deleting networks 2868.4 Copying an IBP configuration 2878.5 Copying configuration 2889 Defining and assign

Pagina 342

3 Installation and uninstallationIf you selected Select address ranges for IO Virtualization, the fol-lowing window opens:In this window, specify whic

Pagina 343

Validity of MAC address input is not checked. Please advance to thenext screen after confirming your input address is valid.The validity of the MAC ad

Pagina 344

3 Installation and uninstallationIn this window, specify which address range the Virtual-IO Managershould use for virtual WWN addresses. The virtual W

Pagina 345

10. Click Next to launch the License Manager.11. Click Register new license.Enter at least one valid license here so that you can use the Virtual-IOMa

Pagina 346

3 Installation and uninstallation13. In the final screen you may view the release notes or the installation log.14. Click Finish to end the installati

Pagina 347

[ --check-prerequisites][ --lang[ en|ja]][ -u|--upgrade][ -q|--quiet][ -f|--force][ -i|--installdir][ -v|--verbose][ -h|--help]Command line parameters

Pagina 348

3 Installation and uninstallationMAC4Range 00:19:99:3F:30:61 - 00:19:99:3F:4F:A0MAC5Range 00:19:99:3F:4F:A1 - 00:19:99:3F:6E:E0MAC6Range 00:19:99:3F:6

Pagina 349

WWN2Range 50:01:99:93:EF:1E:0E:00 - 50:01:99:93:F1:12:0B:FFWWN3Range 50:01:99:93:F1:12:0C:00 - 50:01:99:93:F3:06:09:FFWWN4Range 50:01:99:93:F3:06:0A:0

Pagina 350

3 Installation and uninstallationjaJapanese--upgrade|-uRun installation in upgrade mode if you upgrade from one VIOM versionto another--quiet|-qSilent

Pagina 351 - /etc/init.d/viom_backup start

/var/log/fujitsu/ServerViewSuite/viomDirectory in which the VIOM log files are stored.3.4.4 Collecting diagnostic informationSometimes it might be nec

Pagina 352

12.3.8 The FCBootConfiguration element 32712.3.9 The DCBConfiguration element 32912.3.10 The FunctionConfiguration element 32913 VIOM scenarios 33113.

Pagina 353 - 15 Appendix

3 Installation and uninstallationOnce the update installation is complete, the final window of the installationwizard confirms that the update install

Pagina 354 - 15.2 VIOM address ranges

l If you do not have a valid license, you cannot log in to the VIOM Man-ager.l If the number of currently assigned server profiles exceeds the numbero

Pagina 355

3 Installation and uninstallation2. Click Register new license.Enter a valid license here. You can also enter several licenses by click-ing Register n

Pagina 356 - 15.3 Creating diagnostic data

2. Select the relevant license and click Deregister licenses. The selectedlicense is deleted. If the number of allowed assignments is smaller thanthe

Pagina 357 - StartOptions=--debug trace

3 Installation and uninstallation3. The information displayed includes the following:l License codel Validity period (only relevant for demo licenses)

Pagina 358

When you need to uninstall existing ServerView Operations Man-ager and install the new one, you should uninstall existing Virtual-IOManager:l Save you

Pagina 359 - 15.4 Event logging

3 Installation and uninstallationLOG ON (FILENAME='<data_path>\ViomDB_log.LDF')FOR ATTACHDBCC UPDATEUSAGE('ViomDB')l In the

Pagina 360

4 ConfigurationIn the following sections, you find information on the required configurationson the managed server.4.1 Configurations on the managed B

Pagina 361

4 Configurationin fabric 2. FC switch blades do not support any dedicated network con-nections, but just the virtualization of the I/O parameters inst

Pagina 362

l You cannot mix LAN and IBP modules within a fabric.l You can only assign profiles if no networks are defined for their ports.You can force the assig

Comentarios a estos manuales

Sin comentarios