236 iRMC S2/S3
Server Management Information - Configuring the server settings
Proceed as follows:
Ê Check or uncheck the option(s) under Enabled for the Software Watchdog
and/or Boot Watchdog.
Ê If you have activated either of these options, you can configure the following
settings after Software Watchdog and/or Boot Watchdog:
Continue
No action is performed when the watchdog has expired, i.e. the
server continues to run. An entry is made in the event log.
Reset
The server management software triggers a system reset.
Power Cycle
The server is powered down and immediately powered up again.
Ê As appropriate, enter the time (in minutes) after which this action is to be
performed following after timeout delay.
I The boot watchdog must wait until the system has been started. You
therefore have to specify a sufficient period for after timeout delay (1 -
100).
Ê Click Apply button.
The configured settings are saved and the actions which have been
configured are performed in the appropriate circumstances.