Managing Faults 37
Detect Faults (ILOM show faulty Command)
At the -> prompt, type the show faulty command.
The following show faulty command examples show the different kinds of
output from the show faulty command:
Example of the show faulty command when no faults are present:
Example of the show faulty command displaying an environmental fault:
Example of the show faulty command displaying a configuration fault:
Note – Environmental and configuration faults automatically clear when the
environmental condition returns to the normal range of when the configuration fault
is addressed.
-> show faulty
Target | Property | Value
--------------------+------------------------+-------------------------------
-----------------------------------------------------------------------------
-> show faulty
Target | Property | Value
--------------------+------------------------+-------------------------------
/SP/faultmgmt/0 | fru | /SYS/MB/FT1
/SP/faultmgmt/0 | timestamp | Dec 14 23:01:32
/SP/faultmgmt/0/ | timestamp | Dec 14 23:01:32 faults/0
/SP/faultmgmt/0/ | sp_detected_fault | TACH at /SYS/MB/FT1 has
faults/0 | | exceeded low non-recoverable
| | threshold.
-> show faulty
Target | Property | Value
------------------+----------------------+-----------------------------------
/SP/faultmgmt/0 | fru | /SYS
/SP/faultmgmt/0 | timestamp | Mar 17 08:17:45
/SP/faultmgmt/0/ | timestamp | Mar 17 08:17:45
faults/0 | |
/SP/faultmgmt/0/ | sp_detected_fault | At least 2 power supplies must
faults/0 | | have AC power
Vista de pagina 58