177
CHAPTER 2 DEPENDENCE FUNCTIONS
2.3.6.5 Specify Displaying Trace Data Storage Status
The data display start position in the trace buffer can be specified by inputting a step
number or frame number using the SHOW TRACE command. The data display range can
also be specified.
Specifying Displaying Trace Data Start
Specify the data display start position in the trace buffer by inputting a step number or frame number using
the SHOW TRACE command. The data display range can also be specified.
[Example]
- In Single Trace Mode
>SHOW TRACE/CYCLE -6 ; Start displaying from frame -6
>SHOW TRACE/CYCLE -6..0 ; Display from frame -6 to frame 0
>SHOW TRACE -6 ; Start displaying from frame -6
>SHOW TRACE -6..0 ; Displays from frame -6 to frame 0