ioxadm(8)
System Administration 95
EXAMPLE 9 Enabling the Indicator for Power Supply 1 When Power Supply 1 Has a
Fault Indication
The External I/O Expansion Unit chassis white LED has an integrated push button.
The button can be used to toggle the state of the chassis white locator LED between
off and fast. If the push button is used to turn off the locator LED, fast blink FRU
service LEDs are cleared.
EXIT STATUS The following exit values are returned:
XSCF> ioxadm locator on iox@x031/ps1
XSCF> ioxadm locator
Location Sensor Value Resolution Units
IOX@X031 LOCATE Fast - LED
XSCF> ioxadm env -1 iox@x031/ps1 SERVICE
Location Sensor Value Resolution Units
IOX@X031/PS1 SERVICE On - LED
0 Successful completion.
>0 An error occurred.