Servicing Boards and Components 157
Front Control Panel Light Pipe Assemblies
Overview
The front control panel light pipe assemblies are mounted on each side of the hard
drive cage. You must remove the hard drive cage to access the screws that attach the
light pipe assemblies to the hard drive cage.
Remove the Front Control Panel Light Pipe
Assemblies
1. Remove the hard drive cage.
See “Remove the Hard Drive Cage” on page 146.
2. Remove the No. 1 Phillips screws securing the front control panel light pipe
assembly to the hard drive cage.
Two screws secure the assembly to the hard drive cage in the SPARC Enterprise
T5120 server.
Three screws secure the assembly to the hard drive cage in the SPARC
Enterprise T5220 server.
The following figure illustrates installation of the front control panel light pipe on
a SPARC Enterprise T5220 server. Except for minor differences, such as the
number of screws, installation is the same for SPARC Enterprise T5120 servers.