92 SPARC Enterprise T5440 Server Service Manual July 2009
The following LEDs are lit when a power supply fault is detected:
Front and rear Service Required LEDs
Rear PS Failure LED on the bezel of the server
Fault LED mode on the faulty power supply
The front and rear panel Service Required LEDs are also lit if the system detects a
power supply fault.
See “Front Panel LEDs” on page 4 and “Rear Panel LEDs” on page 7 for more
information about identifying and interpreting system LEDs.
See “Power Supply LED” on page 91 for specific information about power supply
status LEDs.
Related Information
“Managing Faults” on page 9
“Hot-Pluggable and Hot-Swappable Devices” on page 72
“Front Panel LEDs” on page 4
“Rear Panel LEDs” on page 7
Servicing PCIe Cards
Up to eight low-profile PCIe cards may be installed in the system. All slots are wired
to x8 PCIe lanes. Slot 1 and Slot 7 support graphics cards with x16 connectors. Slot 4
and Slot 5 also support 10-Gbyte Ethernet cards (XAUI cards). When a XAUI card is
installed, a PCIe card cannot be installed in the same slot.
Related Information
“PCIe Device Identifiers” on page 96
Green AC present/system
powered on
System is powered on.
Blinking amber Fault Voltage overcurrent or other power fault.
Amber Fault Internal power supply failure or power supply
fan failure.
TABLE: Power Supply Status LEDs (Continued) (Continued)