96 SPARC Enterprise T5440 Server Service Manual July 2009
PCIe Device Identifiers
TABLE: PCIe Device Identifiers on page 96 describes device and device identifiers for
PCIe cards. Device identifiers are case-sensitive.
Note PCIe names in ILOM messages are displayed with the full FRU name, such
as /SYS/MB/PCIE0.
Note In the Solaris OS, PCIe slot addresses are associated with CMP modules. The
PCIe slot address in the Solaris OS might change if you add or remove CMP
modules, or if a CMP module is brought offline. For more information, see the
SPARC Enterprise T5440 Server Product Notes.
Related Information
“Managing Faults” on page 9
“PCIe Slot Configuration Guidelines” on page 97
“System Bus Topology” on page 162
“Performing Node Reconfiguration” on page 155
TABLE: PCIe Device Identifiers
Device Device Identifier Notes
PCIe0 /SYS/MB/PCIE0 x8 slot
PCIe1 /SYS/MB/PCIE1 x16 slot operating at x8
PCIe2 /SYS/MB/PCIE2 x8 slot
PCIe3 /SYS/MB/PCIE3 x8 slot
PCIe4
(XAUI0)
/SYS/MB/PCIE4 or
/SYS/MB/XAUI0
x8 slot; shared with XAUI slot
PCIe5
(XAUI1)
/SYS/MB/PCIE5 or
/SYS/MB/XAUI1
x8 slot; shared with XAUI slot
PCIe6 /SYS/MB/PCIE6 x16 slot operating at x8
PCIe7 /SYS/MB/PCIE7 x8 slot