Fujitsu SPARC T5440 Manual de usuario Pagina 79

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 214
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 78
Managing Faults 53
Note In the ILOM shell there is no notification when the system is actually
powered off. Powering off takes about a minute. Use the show /HOST command to
determine if the host has powered off.
ILOM-to-ALOM CMT Command
Reference
TABLE: ALOM CMT Parameters and POST Modes on page 56 describes the typical
commands for servicing a server. For descriptions of all ALOM CMT commands,
issue the help command or refer to the following documents:
Integrated Lights Out Manager 3.0 Concepts Guide
Integrated Lights Out Manager 3.0 Supplement for SPARC Enterprise T5440 Server
TABLE: Service-Related Commands
ILOM Command ALOM CMT Command Description
help [command] help [command] Displays a list of all available
commands with syntax and
descriptions. Specifying a command
name as an option displays help for
that command.
set /HOST/send_break_action
true
break [-y][-c][-D]
-y skips the confirmation
question.
-c executes a console command
after the break command
completes.
-D forces a core dump of the
Solaris OS.
Takes the host server from the OS to
either kmdb or OpenBoot PROM
(equivalent to a Stop-A), depending
on the mode Solaris software was
booted.
set
/SYS/component/clear_fault_a
ction true
clearfault UUID Manually clears host-detected
faults. The UUID is the unique fault
ID of the fault to be cleared.
start /SP/console console [-f]
-f forces the console to have read
and write capabilities.
Connects you to the host system.
Vista de pagina 78
1 2 ... 74 75 76 77 78 79 80 81 82 83 84 ... 213 214

Comentarios a estos manuales

Sin comentarios