Servicing Customer-Replaceable Units 109
If the show faulty command does not report a fault with a UUID, then you
do not need to proceed with the following step because the fault is cleared.
6. Run the set command.
Add FB-DIMMs
If you are upgrading the system with additional FB-DIMMs, use this procedure.
Before you begin, complete these tasks:
Read the section, “Safety Information” on page 59.
Read the sections, “Supported FB-DIMM Configurations” on page 110 and
“FB-DIMM Device Identifiers” on page 112.
Power off the server using one of the methods described in the section, “Powering
Off the System” on page 63.
“Extend the Server to the Maintenance Position” on page 66
“Perform Electrostatic Discharge Antistatic Prevention Measures” on page 69
“Remove the Top Cover” on page 69
“Remove a CMP/Memory Module” on page 99
1. Unpackage the FB-DIMMs and place them on an antistatic mat.
2. Ensure that the ejector tabs are in the open position.
3. Line up the FB-DIMM with the connector.
Align the FB-DIMM notch with the key in the connector. This ensures that the
FB-DIMM is oriented correctly.
/SP/faultmgmt/0 | timestamp | Dec 14 22:43:59
/SP/faultmgmt/0/ | sunw-msg-id | SUN4V-8000-DX
faults/0 | |
/SP/faultmgmt/0/ | uuid | 3aa7c854-9667-e176-efe5-e487e520
faults/0 | | 7a8a
/SP/faultmgmt/0/ | timestamp | Dec 14 22:43:59
faults/0 | |
-> set /SYS/MB/CPU0/CMP0/BR0/CH1/D0 clear_fault_action=True
Are you sure you want to clear /SYS/MB/CPU0/CMP0/BR0/CH1/D0 (y/n)? y
Set ’clear_fault_action’ to ’true