Servicing Customer-Replaceable Units 105
Remove FB-DIMMs
Before you begin, complete these tasks:
Read the section, “Safety Information” on page 59.
Power off the server, using one of the methods described in the section, “Powering
Off the System” on page 63.
“Extend the Server to the Maintenance Position” on page 66
“Perform Electrostatic Discharge Antistatic Prevention Measures” on page 69
“Remove the Top Cover” on page 69
“Remove a CMP/Memory Module” on page 99
Do the following:
1. If you are removing a faulty FB-DIMM, determine which FB-DIMM you want
to remove.
a. Press the FB-DIMM fault button.
See “FB-DIMM Fault Button Locations” on page 113.
b. Note which FB-DIMM fault LED is illuminated.
2. Push down on the ejector tabs on each side of the FB-DIMM until the
FB-DIMM is released.
Caution FB-DIMMs might be hot. Use caution when servicing FB-DIMMs.
3. Grasp the top corners of the faulty FB-DIMM and remove it from the
CMP/memory module.
4. Place the FB-DIMM on an antistatic mat.
5. Repeat Step 2 through Step 4 to remove any additional FB-DIMMs.
Install FB-DIMMs
1. Unpackage the replacement FB-DIMMs and place them on an antistatic mat.
Tip See “Supported FB-DIMM Configurations” on page 110 for information about
configuring the FB-DIMMs.
2. Ensure that the ejector tabs are in the open position.