Fujitsu SPARC T5440 Manual de usuario Pagina 162

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 214
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 161
136 SPARC Enterprise T5440 Server Service Manual July 2009
“Remove a Fan Tray” on page 83
Note You must remove all four fan trays.
“Remove the Fan Tray Carriage” on page 129
1. Remove the CMP/memory module bracket.
The bracket is secured with six captive No. 2 Phillips screws. See FIGURE:
CMP/Memory Module Bracket Captive Screw Locations on page 136.
FIGURE: CMP/Memory Module Bracket Captive Screw Locations
2. Remove the flex cable retainer.
Loosen the captive No.2 Phillips screw and lift the retainer up and out of the
chassis.
3. Unplug the flex cable from J9801 on the motherboard.
4. Unplug the auxiliary power cable from J9803 on the motherboard.
Vista de pagina 161
1 2 ... 157 158 159 160 161 162 163 164 165 166 167 ... 213 214

Comentarios a estos manuales

Sin comentarios