Chapter 9 Power Supply Unit (PSU) Replacement 9-11
a. Perform operation according to instructions of messages. When the display
of the maintenance menu returns to the initial page, the operation is
completed.
b. Exit the maintenance menu.
9. Confirm that the replacement components are normal by using the
showhardconf or showstatus command of XSCF.
Unless "*" is displayed for the replacement PSU, it is operating normally.
For details of the showhardconf command and showstatus command, see the
SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers XSCF Users Guide,
the SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers XSCF Reference
Manual, or the man page.
Note The showstatus command displays information on degraded components.
10. Close the door on the server, and lock it.
9.3 Cold Replacement
In cold replacement, none of the replacement work is performed with the
maintenance menu from a terminal connected to XSCF.
The procedure is as follows.
1. Unlock and open a door of the server.
For details, see Chapter 5.
2. Change the mode switch setting on the operator panel from Locked to Service.
Note When the maintenance work is completed, be sure to confirm the mode
switch setting and return the switch to Locked.
3. Stop (turn off power) all domains together. Take either of the following two
actions:
Press and hold the POWER switch on the operator panel for at least four
seconds.