Fujitsu SPARC ENTERPRISE M8000 Manual de usuario Pagina 377

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 514
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 376
Chapter 20 Backplane Replacement 20-21
13. Start (turn on power) all domains together. Take either of the following two
actions:
Press and hold down (for less than four seconds) the POWER switch on the
operator panel.
From a console that is connected to XSCF, execute the poweron -a command
of XSCF.
The power to all the domains is turned on, and then the power-on self test (POST)
is executed. When ok prompt displayed on the console of relevant domain, POST
is completed.
For details of the power-on operation, see Section 4.4.2, “Powering the Server On”
on page 4-19, and the SPARC Enterprise M3000/M4000/M5000/M8000/M9000
Servers XSCF Users Guide.
14. Restore the original mode switch setting on the operator panel.
20.2.3 FAN BP
FIGURE 20-13, FIGURE 20-14, and FIGURE 20-15 show the mounting locations of FAN BPs
of M8000, M9000 (base cabinet), and M9000 (with the expansion cabinet),
respectively.
Vista de pagina 376
1 2 ... 372 373 374 375 376 377 378 379 380 381 382 ... 513 514

Comentarios a estos manuales

Sin comentarios