Chapter 20 Backplane Replacement 20-21
13. Start (turn on power) all domains together. Take either of the following two
actions:
■ Press and hold down (for less than four seconds) the POWER switch on the
operator panel.
■ From a console that is connected to XSCF, execute the poweron -a command
of XSCF.
The power to all the domains is turned on, and then the power-on self test (POST)
is executed. When ok prompt displayed on the console of relevant domain, POST
is completed.
For details of the power-on operation, see Section 4.4.2, “Powering the Server On”
on page 4-19, and the SPARC Enterprise M3000/M4000/M5000/M8000/M9000
Servers XSCF User’s Guide.
14. Restore the original mode switch setting on the operator panel.
20.2.3 FAN BP
FIGURE 20-13, FIGURE 20-14, and FIGURE 20-15 show the mounting locations of FAN BPs
of M8000, M9000 (base cabinet), and M9000 (with the expansion cabinet),
respectively.