Chapter 22 Media Backplane Replacement 22-9
From a console that is connected to XSCF, execute the poweron -a command
of XSCF.
The power to all the domains is turned on, and then the power-on self test (POST)
is executed. When ok prompt displayed on the console of relevant domain, POST
is completed.
For details of the power-on operation, see Section 4.4.2, “Powering the Server On”
on page 4-19, and the SPARC Enterprise M3000/M4000/M5000/M8000/M9000
Servers XSCF Users Guide.
14. Restore the original mode switch setting on the operator panel.
Note When the maintenance work is completed, be sure to confirm the mode
switch setting and return the switch to Locked.
15. Close the door on the server, and lock it.