Fujitsu SPARC ENTERPRISE M8000 Manual de usuario Pagina 296

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 514
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 295
13-22 SPARC Enterprise M8000/M9000 Servers Service Manual August 2009
Press and hold down (for less than four seconds) the POWER switch on the
operator panel.
From a console that is connected to XSCF, execute the poweron -a command
of XSCF.
The power to all the domains is turned on, and then the power-on self test (POST)
is executed. When ok prompt displayed on the console of relevant domain, POST
is completed.
For details of the power-on operation, see Section 4.4.2, “Powering the Server On”
on page 4-19, and the SPARC Enterprise M3000/M4000/M5000/M8000/M9000
Servers XSCF Users Guide.
14. Restore the original mode switch setting on the operator panel.
Note When the maintenance work is completed, be sure to confirm the mode
switch setting and return the switch to Locked.
15. Close the door on the server, and lock it.
Vista de pagina 295
1 2 ... 291 292 293 294 295 296 297 298 299 300 301 ... 513 514

Comentarios a estos manuales

Sin comentarios