14-10 SPARC Enterprise M8000/M9000 Servers Service Manual August 2009
6. Connect the wrist strap clip to a cabinet grounding port, and attach the band of
the wrist strap to one of your wrists.
7. Remove the CD-RW/DVD-RW drive unit to be replaced. (See
FIGURE 14-4 or
FIGURE 14-5)
a. Using a Phillips screwdriver, loosen the two knob screws securing the
CD-RW/DVD-RW drive unit.
b. While grasping the knob screws, pull out the CD-RW/DVD-RW drive unit
slowly from the slot.
8. Place the removed CD-RW/DVD-RW drive unit on an antistatic conductive mat.
9. Mount the replacement CD-RW/DVD-RW drive unit by following the removal
instructions in Step 7 in reverse order.
Caution Do not forcibly push the CD-RW/DVD-RW drive unit in when inserting
it. If the CD-RW/DVD-RW drive unit is forcibly inserted despite the presence of any
obstruction in a slot or any problems with the connector pin, serious damage may
result.
10. Attach the CD-RW/DVD-RW drive unit to the port.
Execute the cfgdevice -c attach -p <port no.> command of XSCF.
11. Confirm that the replacement CD-RW/DVD-RW drive unit is configured to the
domain.
From XSCF, execute the cfgdevice -l command to confirm that the specified port
number is displayed in the current connection.
12. Turn on the power to the relevant domain.
From a console that is connected to XSCF, execute the poweron -d command of
XSCF.
For details of the power-on operation, see Section 4.4.2, “Powering the Server On”
on page 4-19, and the SPARC Enterprise M3000/M4000/M5000/M8000/M9000
Servers XSCF Users Guide.
13. Start up domains as necessary.
14. Close the door on the server and lock it.
Vista de pagina 305